LOGIC ANALYSER MODEL

Overview

The VSM Logic Analyser is supplied as standard with both ProSPICE Professional.

A logic analyser operates by continuously recording incoming digital data into a large capture buffer. This is a sampling process, so there is an adjustable Capture Resolution, which defines the shortest pulse that can be recorded. A Trigger section monitors the incoming data and causes the data capture process to stop a certain time after the triggering condition has arisen; capturing is started by arming the instrument. The result is that the contents of the capture buffer both before and after the trigger time can be displayed. Since the capture buffer is very large (40000 samples, in this case) a means of zooming and panning the display is provided.  Finally, movable measurement cursors allow accurate timing measurements of pulse widths and so forth.

Channel selection on the display is dynamic, mapping onto those lines that have been wired on the schematic. Trigger conditions by default are 'any' but can be constrained to edges or levels via the triggers button at the bottom right of the display.

 

The logic analyser can act as a popup window (the default) or be docked at the bottom of the simulation by dragging it down. The benefit of the latter is that is does not obscure parts of the schematic design at various zoom levels. You can always then detach the instrument into a popup window again from the icon at the right hand side of the docked instrument.

The VSM Logic Analyser models a basic 24 channel unit specified as follows:

  • Up to 16 x 1 bit traces and 4 x 8 bit bus traces.
  • 40000 x 52 bit capture buffer.
  • Capture resolution from 200us per sample to 0.5ns per sample with corresponding capture times from 4s to 10ns.
  • Display zoom range from 1000 samples per division in to 1 sample per division.
  • Triggering on ANDed combination of input states and/or edges, and bus values.
  • Trigger position can be changed from –50% to +50% of the capture buffer.
  • Cursors provided for taking accurate timing measurements.

Using the Logic Analyser

To capture and display digital data

  1. Pick the LOGIC ANALYSER object by selecting the Meter icon in ISIS and then selecting the Logic Analyser from the Object Selector.

  2. Start an interactive simulation by pressing the play button on the Animation Control Panel.  The logic analyser popup window should appear.
  3. Set the Resolution dial to a value suitable for your application. This represents the smallest width of pulse that can be recorded. The finer the resolution, the shorter will be the time during which data is captured.

  4. Click on the triggers button at the bottom right of the instrument and set or refine the trigger conditions for the active lines. For example, if you want to trigger the instrument when the signal connected to channel 1 is high and the signal connected to channel 3 is a rising edge, you would change the combo box at channel 1 to “High” and the third one to “Low-High”.

  5. When you are ready, click the Capture button to arm the instrument. The Capture button will light by pink colour. The logic analyser will now wait for trigger event and capture incoming data continuously whilst monitoring the inputs for the trigger condition. When this occurs, the Capture button will light by green colour. Data capture will then continue until the part of the capture buffer after the trigger position is full, at which point the Capture button will extinguish and the captured data will appear in the display.
  6. The position of the screen display after the trigger point can be adjusted using the scrollbar at the bottom of the display.

Panning and Zooming

Since the capture buffer holds 10000 samples, and the display is only 400 pixels wide, a means is needed to pan and zoom within the capture buffer. The Display Scale dial determines the number of samples per division, whilst the scroll-bar attached to the display itself allows you to pan left and right.

Note that he readout located beneath the Display Scale dial displays the current time per division in seconds, not the actual setting of the dial itself. The division time is calculated by multiplying the zoom setting by the resolution.

Taking Measurements

Adjustable cursors are provided which can be used for taking accurate time measurements. To use this feature lit up the  Cursors button. To set absolute cursor into screen just move the mouse to appropriate position and press left mouse button. To set different cursor, move mouse left and right while left button is depressed. Cursors can be moved by mouse (while mouse is over any lines of the cursor) as well as deleted using the context menu – items “Delete Cursor” or “Clear All Cursors”.

Printing

Current waveform displayed on the screen can be printed using context menu item “Print…”.

Colours

Colours of each channel can be changed in settings dialog which one can be opened from the context menu command.